Motor ECN/ECR Dashboard
Browse and filter 1550 Motor (MP) engineering change records
1550
Total Records
440
ECN
1110
ECR
96
High Severity
595
Medium Severity
2025 vs 2026 Year-over-Year Comparison
| Metric | 2025 | 2026 | Change |
|---|---|---|---|
| Total Records | 1125 | 425 | -700 (-62%) |
| ECN | 306 | 134 | -172 (-56%) |
| ECR | 819 | 291 | -528 (-64%) |
| High Severity | 81 | 15 | -66 (-81%) |
| Medium Severity | 429 | 166 | -263 (-61%) |
| Low Severity | 615 | 244 | -371 (-60%) |
| Avg / Month | 102.3 | 106.3 | +3.9% |
| High Severity Rate | 7.2% | 3.5% | -3.7pt |
2025: 11 months of data | 2026: 4 months of data
Loading...
Category share
Category Overview
AI Root Cause Analysis (1550 records)
Failure modes
1550 records rolled up into 15 failure modes (1465 classified)
85 unclassified
Action priority:In this BOM:S/O/D are derived from the ECN/ECR text by rules, not from a measured FMEA. Hover a number for the rule and the phrase behind it.
| Failure mode | Matched wording | |||||||
|---|---|---|---|---|---|---|---|---|
| Process / communication miss | 560 (36%) | 10 | 10 | 7 | H | – | 2026-04-01 | was not requested | Order Entry Error | INTERNAL SUGGESTION | CORRECTION TO ORDER | QUOTATION ERROR |
| Customer-requested change | 496 (32%) | 5 | 10 | 7 | H | – | 2026-04-01 | Customer Request | CUSTOMER CHANGE | MARKETING REQUEST |
| Quantity / BOM structure | 110 (7%) | 9 | 6 | 7 | H | – | 2026-03-31 | ADD | remove | REPLACE | added | QTY | BOM |
| Bearing / shaft | 44 (3%) | 10 | 4 | 8 | H | – | 2026-03-31 | VIBRAT | BALANCE | BEARING | COUPLING | SHAFT | SEAL |
| Bracket / mounting | 38 (2%) | 7 | 4 | 7 | H | – | 2026-03-23 | bracket | mount |
| Wiring / connection | 36 (2%) | 7 | 4 | 7 | H | – | 2026-03-27 | TERMINAL | wire | CONDUIT | CABLE |
| Dimension / fit | 28 (2%) | 8 | 4 | 7 | H | – | 2026-03-20 | FIT | CLEARANCE | INTERFER | dimension | shorten | LENGTH |
| Insulation / grounding | 27 (2%) | 10 | 4 | 8 | H | – | 2026-03-30 | STATOR | rotor | WINDING | GROUND | insulat | VOLTAGE |
| Thermal / cooling | 27 (2%) | 9 | 4 | 7 | H | – | 2026-03-30 | GREASE | FAN | HEAT | OILER | temperature |
| Labeling / documentation | 25 (2%) | 10 | 4 | 7 | H | – | 2026-03-26 | NAMEPLATE | document | ID TAG | label |
| Test / certification | 24 (2%) | 9 | 4 | 8 | H | – | 2026-03-25 | witness | TEST | CSA | inspect |
| BOM or drawing data error | 20 (1%) | 7 | 4 | 7 | H | – | 2026-03-12 | UPDATE OUTLINE DRAWING | REVISE OL DRAWING | CORRECT MAGNETIC WEDGE IN BOM | UPDATE PARTS QUANTITIES ON BOM | UPDATE HARDWARE ON BOM | UPDATE OUTLINE AND AUX BOXES DRAWING |
| Enclosure / sheet metal | 17 (1%) | 7 | 4 | 7 | H | – | 2026-03-30 | gasket | PAINT | COVER |
| Part availability / lead time | 11 (1%) | 7 | 4 | 7 | H | – | 2026-03-11 | OBSOLET | AVAILIB | instead of | AVAILAB |
| Control / protection device | 2 (0%) | 3 | 3 | 8 | L | – | 2026-02-05 | SWITCH |
| Not matched by any rule | 85 (5%) | 7 | 6 | 7 | H | – | 2026-03-18 | – |